Oct 19, 2017 · Worcester-Bosch 240 Combi Boiler - Pressure help. I'd be checking pressure vessel is pumped up to correct level (1 bar?) before re-pressuring the system with water. fire up boiler. Importantly, make sure a carbon monoxide alarm is fitted in the same room as the boiler, preferably slightly higher on the wall adjacent.
Read MoreThis Worcester Bosch gas condensing combi boiler is the perfect size to provide heat and instant water in small to medium-sized homes with a single bathroom. Choose it to fit out new flats, houses or smaller offices. This unit has a modern design, operates quietly and is easy to use thanks to its full-colour text display and wireless connectivity.
Read MoreFeb 22, 2018 · Hope someone can help. Have a two year old Worcester Bosch boiler that is losing pressure. Had WB come out and replace PRV under warranty but still got pressure drop. However outside there are TWO overflows from the boiler.one copper pipe from the PRV and one white plastic from somewhere else within the boiler.
Read MoreFeb 03, 2022 · Go no hot water, low boiler pressure, or one that's failing to fire up altogether? No worries. This 10-minute guide to Worcester boilers problems will list typical boiler faults, explain what they mean, and recommend solutions.. We've also referenced detailed articles on each of the Worcester boilers problems listed, so you can get in-depth knowledge about each …
Read MoreWorcester Bosch boiler warranty. The majority of Worcester Bosch boilers come with 2 years of warranty of standard, although with some models this extends a bit further to 5 years. Use our complete guide to Worcester Bosch warranties for more information.
Read MoreThe boilers require a gas flow in m3/h of: NG (G20) LPG (G31) 24CDi 2.9 1.13 28CDi 3.3 1.3 35CDiII 4.16 1.6 The meter governor or regulator should deliver a dynamic pressure of 20mbar for natural gas or 37mbar for propane at the appliance, which is about 18.5mb or 35.5 mbar at gas valve inlet pressure test point.
Read MoreOct 15, 2010 · i have a worcester cd35i ii combi boiler which now has created a problem the pressure of the unit is just over 1 bar and when you turn either the central heating or the hot water all goes well the relevant lights come on and the pilot light kicks in and it all fires up, the pressure slowly raises to 1.5bar then you get a knocking noise as if it has a air lock and the pressure …
Read MoreBoiler pressure is one of the most common faults associated with the heating system, however there is an easy fix. When the heating system is cool, the pressure should be between 1 and 1.5 bar on the pressure gauge. Watch our video on how to repressurise your system here.
Read MoreApr 22, 2012 · Discuss Worcester Bosch 24 combi boiler in the Central Bosch Worcester Gr8300iw 30 C pressure loss and temperature boiler control copper cylinder drain engineer expansion fault fitting flow flue flush free gas gas engineer gas safe head heating hello help high hose hot hot water ideal install installation job jobs kitchen leak leaking
Read MoreJan 03, 2015 · I fear you need a boiler cove to have a looksee, Debs. Your sealed system doesn't seem to be showing the 'normal' symptoms of a knackered exp vessel; it does seem as tho' something unusual is going on if you have released a couple of jugs worth of water and the pressure is still up at 2.5bar (almost the max 'allowed') when cold. Usually, with a faulty/empty …
Read MoreSep 05, 2010 · hi, i have a worcester bosch 28cdi combi boiler.the pressure gauge rises from 1.3bar to over 3bar in about 90mins.i have just replaced the filling loop assembly and the pressure valve but it has not solved it. about 18 to 24 months ago i replaced the water to water heat exchanger.the boiler is 8 years old.any ideas what to do next ! Thanks.also no moisture comes …
Read MoreMar 27, 2010 · Hi, Hoping someone on here can help me clarify the water regs on my problem: Had a worcester bosch combi boiler installed in Nov last year, had no probs until last night, replaced a radiator, then re-pressurised the boiler back to just over 1 bar, then after about 3 hours, it made a very funny noise and lost all pressure, it wouldnt then refill and started leaking from …
Read MoreJan 25, 2013 · We have a British Gas Worcester Bosch C1 combi boiler. When we have the heating on the pressure gauge needle sits at 4, which is the max. It's been off the last few months, but we've had it on and off over the last couple of days. It was switched off at 9am this morning. It is now 3.15pm and the needle is sitting just below 2.
Read MoreWorcesterBoiler Manuals. Listed below are all the manuals for Worcester. Just click on the model or the Gas council number and the manual will download at the bottom of the page. After you have downloaded the manual double click on the download for the manual to open, if you want to save the download right click.
Read MoreSep 03, 2019 · Make sure the filling loop is shut, then bleed a radiator to reduce the pressure it will take a while to get it to between 1-1.5bar. If the pressure goes back up you need a professional to have a look at it. powerflushingpro, 26 Mar 2011. #2.
Read MoreThe Worcester Bosch Greenstar 24i Junior has been discontinued. Designed and manufactured by Worcester Bosch, the Greenstar 24i Junior is a highly reliable condensing combi gas boiler, ideal for medium-sized homes. Which boiler has replaced this model? This unit has been replaced by the Worcester Bosch Greenstar 24 kW combi gas boiler.
Read MoreDec 07, 2021 · If your boiler is sitting between 1-2 bar (1.5 bar is the ideal boiler pressure), then the pressure isn't the problem. More likely, the pressure sensor is producing incorrect readings. The water pressure sensor's job is to tell the Printed …
Read MoreJun 20, 2014 · Liam General advice re a 10 year old boiler, Alpha CB28 (iirc) and a possible blocked heat exchange unit. Its my dads and he has BG service contract and the last guy took it all apart and flushed the heat exchanger, now getting hot …
Read MoreBoiler pressure is one of the most common faults associated with the heating system, however there is an easy fix. When the heating system is cool, the pressure should be between 1 and 1.5 bar on the pressure gauge. Watch our video on how to repressurise your system here.
Read MoreOct 15, 2010 · i have a worcester cd35i ii combi boiler which now has created a problem the pressure of the unit is just over 1 bar and when you turn either the central heating or the hot water all goes well the relevant lights come on and the pilot light kicks in and it all fires up, the pressure slowly raises to 1.5bar then you get a knocking noise as if it has a air lock and the pressure …
Read MoreThe Worcester Bosch Greenstar 24i Junior has been discontinued. Designed and manufactured by Worcester Bosch, the Greenstar 24i Junior is a highly reliable condensing combi gas boiler, ideal for medium-sized homes. Which boiler has replaced this model? This unit has been replaced by the Worcester Bosch Greenstar 24 kW combi gas boiler.
Read MoreDec 17, 2010 · My pressure is too high on my worcester bosch greenstar 24i junior. how do i turn pressure down please - Answered by a verified Plumber I have a Worcester Bosch Greenstar combi boiler either 24i junior or 28i junior. At the moment I am having an issue with the temperature of the water coming out of shower. Thank you for all your help
Read MoreFeb 07, 2015 · The hot pressure stays absolutely static at 2 bar and the cold pressure stands at 1.5 bar for a fortnight - then the cold pressure goes right down and the boiler fails to fire. Now I know it will happen after 15 days, I am tempted to refresh the pressure on the evening of the 15th day rather than wake to a cold house in the morning.